CA 117-2000

ID

463F82E1A2CA41CCA9F11334CDCEDE1F

文件大小(MB)

0.32

页数:

8

文件格式:

pdf

日期:

2008-4-16

购买:

购买或下载

文本摘录(文本识别可能有误,但文件阅览显示及打印正常,pdf文件可进行文字搜索定位):

STATE OF CALIFORNIA,DEPARTMENT OF CONSUMER AFFAIRS,BUREAU OF HOME FURNISHINGS,AND THERMAL INSULATION,3485 ORANGE GROVE AVENUE,NORTH HIGHLANDS, CA 95660^5595,TECHNICAL BULLETIN 117,Requirements, Test Procedure and Apparatus for,Testing the Flame Retardance of Resilient Filling Materials,Used in Upholstered Furniture,MARCH 2000,1,TECHNICAL BULLETIN 117 11.,Requirements, Test Procedure and Apparatus for Testing,the Flame Retardancs of Resilient Filling Materials Used In,Upholstered Furniture,SECTION A-Part I,Resilient CeHular M日的r消居,I. Rgciuirement,1,The average char length of all specimens shall not,exceed 6 inches.,2 .The maximum char length of any individual specimen,shall not exceed 8 inches,3 . The average afterflame, including afterflame of molten,material or other fragments dropping from specimens,shall not exceed 5 seconds. ,4 .The maximum afterflame of any individual specimen,including afterflame of molten material or other,fragments dropping from the specimen, shall not,exceed 10 seconds,5 .The average afterglow, including afterglow of molten,material or other fragments dropping from the,specimen, shall not exceed 15 seconds.,6 .Resilient cellular materials shall meet the above,requirements both before and after aging for 24 hours in,a forced air circulating oven at 220°F (1O4DC),7,A minimum of 10 test specimens shall be tested: 5,specimens before aging and 5 specimens after aging,81Test requirements for resilient cellular materials shall,be evaluated according to the following sampling,procedure both before and after aging.,Te第 5 Soecimens,t,All specimens,meet all test,criteria,4,Two or Mpre,specimens fail,one or more,criteria,4,One test specimen,fails one or,more test,criteria,1,III.,Material,Passes,Material,Fails,4,T§5t_5 Additional,Tests oecimens,One or more test,J,All specimens,specimens fail one meet all test,or more test criteria,I,criteria,1,T,Material,T,Material,Fails Passes,Test Procedure,L Sgps,This procedure is intended for use in determining,the resistance of resilient cellular materials to flame,and glow propagation and tendency to char.,2. Test5oecknen,Test specimens shall be rectangles of cellular,materials 12 x 3 x 1/2 inches.,3. Anugiratus,3.1, Cabinet - A test cabinet fabricated In,accordance with the requirements of Federal,Test Method Standard No. 191 Method 5903.2,or FF 3-71 shall be used.,32 Bumer - The burner shall be in accordance with,the requirements of Federal Test Method,Standard No. 191 Method 5903.2 or FF 3^71.,3.3. Gas - The test gas shall be Matheson Gas B.,3.4. SpeGimen HMd启r - A stainless steel specimen,holder fabricated in accordance with the,requirements specified in Figure 117-A shall be,used.,4. Pr0mdure,4.1. All specimens shall be tested, and conditioned,for a minimum of 24 hours, at 70 ± 5"F and,less than 55% relative humidity,4.2. The specimen in its holder shall be suspended,vertically in the cabinet in such a manner that,the lower end of the specimen is 0.75 inches,above the top of the burner,4,3. The burner flame shall be adjusted by means,of a needle valve in the base of the burner to,give a flame height of 1.5 inches with air supply,to the burner permanently shut off.,4.4. After inserting the specimen, the burner flame,shall be applied vertically at the middle of the,lower edge of the specimens for 12 seconds,4.5. The cabinet door shall remain shut during,testing.,DHin 计ions,1, Afterflame,The afterflame time shall be the time the specimen,continues to flame after the burner flame is,extinguished, and shall include afterflame of molten,drops of material.,2, Afterctlow,The afterglow time shall be the time the specimen,continues to glow after it has ceased to flame, and,shall include afterglow of molten drops of material.,3. Char 值 Mth,The char length shall be the distance from the end,of the specimen which was exposed to the flame, to,2,the upper edge of the void area. tn the,measurement of char length all readily removable,portions of carbonaceous char shall be removed,prior to measurement.,M Test Results,1. The char length of each specimen shall be,recorded to the nearest 0.1 inches and the,afterflame time and afterglow time to the nearest,0.1 seconds.,2x Maximum and average char length, afterglow and,afterflame, shall be determined for each resilient,cellular material.,SECTION A-PART II,Shredded Resilient Cellular Materials,(e.g.f shredded polyurethane foams),Shredded resilient cellular materials shall meet the,following requirements.,1. The resilient cellular material used for shredding shall,meet the requirements of Section A and D of this,Technical Bulletin prior to shredding, or a post flame,treated shredded foam ma……

……